Product Structure
Conductor: Single-core or stranded bare copper or tinned copper wire complying with VDE 0281 Part 5, HD21.5S3, IEC 227-5. Insulation: Polyvinyl chloride (PVC)/T2 Polyvinyl chloride (PVC) complying with Standard 0281 Part 1 + HD21.1.
Color Code: The cores are identified by colors, conforming to HD402 standard.
Sheath Material: Polyvinyl chloride (PVC)/TM2 type.
Sheath Color: Black (RAL9005).
Standards Applied: <HAR> HD21.5 S3, VDE-0281 voltage directive, 73/23/EEC & 93/68/EEC, IEC 60227-5.
Technical Parameters
Rated Voltage: 300V/300V.
Test Voltage: 2000V complying with DIN VDE 0281 Part 2 + HD21.2.
Minimum Bending Radius Fixed Installation: 4×D (cable outer diameter).
Mobile Installation: 7.5×D (cable outer diameter).
Temperature Range Fixed Installation: -40℃ to +70℃.
Mobile Installation: -5℃ to +70℃.
Flame Retardant: Complies with IEC 60332-1-2 + EN 60332-1-2, UL VW-1 + CSA FT1, IEC 60332.1.
Insulation Resistance: 20MΩ×km.
Characteristics and Compliance
Characteristics: ◆ Compliant with EU harmonized standards. ◆ Ultra-fine conductors, flexible with small bending angles. ◆ Flat structure, economically saving space and capable of withstanding some mechanical external forces.
Compliance Certifications: RoHS/CE.
Typical Applications
Used for internal and external wiring in appliances, instruments, power equipment, and automation devices without forced traction or directional coupling. Suitable for locations with humidity and mixtures of oil and water.